EMF Converter
Release time:2016-03-25 16:18:00 Click on the:
FSC100 Series
(1)Basic Functions
A.Sensor suitable:DN3~DN2800
B.Range of rate:0.01m/s~12m/s
C.Accuracy:Level 0.25
D.Low-frequency square wave or High-frequency Excitation
Excitation frequency:3.125Hz,6.25Hz,12.5Hz,25Hz
E.Excitation Current:100mA ~500mA,Default 160mA or 250mA
F.Language:Display in Chinese,English and other customized
G.Power:86V~265VAC,18V~36VDC
H.Output Signal:1.4-20mA 2.Pulse 3.Frequency 4.High and Low Alarm or Relay
I.Communication:Modbus(RS485),HART,GPRS
J.Display:Instantaneous flow rate,Velocity,Positive accumulation,Negative accumulation,Net accumulation,Signal voltage value
(2)Working Condition
Temperature:-10~60℃
Humidity:5%~95%
Power:86V~265VAC,18V~36VDC Power Consumption<15W(With the sensor)
(3)Basic Format
A.Circular shell
B.Square shell
(4)Sensor Matching Requirements
The signal sensitivity will be 150 microV to 200 microV for 1 m/s
The excitation current can be customized from 100mA to 500mA.
The resistance for each excitation current:
125mA is 100-120 Ohms
160 mA is 60-100 Ohms
250 mA is 40-60 Ohms.
(5)The Machine Accuracy
0.25%,0.5%
(6)Analog Current Output
Load resistance:0-500Ω
The basic error:0.1%±10μA
(7)Digital Frequency Output
Range:1~5000Hz
Output electrical isolation:Optoelectronic isolation.Isolation voltage:More than 1000 VDC.
Frequency output driver:Field effect tube output,Max 36 VDC power supply,Max 250 mA load current.
(8)Digital Pulse Output
The output pulse equivalent is set by client.
The output pulse width:50ms
Output electrical isolation:Optoelectronic isolation.Isolation voltage:More than 1000 VDC.
Pulse output driver:Field effect tube output,Max 36 VDC power supply,Max 250 mA load current.
(9)High and Low Alarm Output
Alarm output:H -High alarm, L -Low alarm
Output electrical isolation:Optoelectronic isolation.Isolation voltage:More than 1000 VDC.
Alarm output driver: Darlington pipe output,Max 36 VDC power supply,Max 250 mA load current.
(10)Electrical Isolation
Insulation voltage between Analog input and Analog output:not less than 500V;
Insulation voltage between Analog input and Alarm power:not less than 500V;
Insulation voltage between Analog input and AC power:not less than 500V;
Insulation voltage between Analog output and AC power:not less than 500V;
Insulation voltage between Analog output and Ground:not less than 500V;
Insulation voltage between Pulse output and AC power:not less than 500V;
Insulation voltage between Pulse output and Ground:not less than 500V;
Insulation voltage between Alarm output and AC power:not less than 500V;
Insulation voltage between Alarm output and Ground:not less than 500V.